J/A-DQ(ZN)BH-R

 

Optical cable – halogen-free, fire retardant, with intensified protection against rodents

 

Construction:

1. Fibres                                             optical fibres with primary protection

2. Tube                                               empty multifibre filled by gel

3. Construction                                  central tensile element, tubes are stranded around central element, bedding of missing tubes by bedding element, layer of aramid tensile fibres, reinforced layer of water-blocking glass fibres, wrapping of the cable core by water-blocking tape

4. Sheath                                            fire retardant halogen-free polymer compound       

5. Variants, the number of fibres       2, 4, 6, 8, 10, 12, 16, 20, 24, 30, 36, 40, 48, 50, 60, 72, 80, 96, 100, 120, 144 

                                                           a variant with a winding yarn under a sheath

 

Technical parameters:

Surrounding temperatures (fixed placement):           - 30°C up to + 70°C

Surrounding temperatures (during installation):       -5°C up to +50°C

Minimum bending radius (fixed placement):            20D

Minimum bending radius (during laying):                15D

 

Basic characteristics:           

Halogen-free, low corrosion of gasses during burning:        IEC 60754-2

Low smoke density during burning:                                     IEC 61034-2

Self-extinguishing:                                                                EN 60332-1-2

Resistant to vertical spread of flame:                                               EN 50266-2-2 category A

Colour marking of fibers 1-12 according to IEC 60304:      red, green, blue, yellow, white, grey, brown, violet, turquoise, orange, black, pink

Colour marking of tubes:                                                      1. red, 2. green, others white

Sheath colour:                                                                       orange

 

Usage:

The cables are used for transmission of optical signals for indoor and outdoor environment with increased protection against rodents and for the environment where is insisted on personal protection, on the protection of equipments, constructions and of materials (e.g. in public spaces, shopping malls, in hospitals, hotels or in tunnel constructions).

The cables can be placed in the environment with the explosion danger (zone 1, 2) providing compliances with the conditions of intrinsic safety according to IEC 60079-11.



up